Now The ice and snow have melted and the cover is getting in deeper. "height": "219",
I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. I have the PF1202T timer on my pool. Wired correctly, #10 wire, nothing. If any of these issues occur your timer will not work properly. I have a inground pool with T10003RT4 control panel. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Hi Joe, could be time, for new timer. I would suggest calling Intermatic and suggesting that idea and a free replacement? If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. "primaryImageOfPage": {
The clock not turning on your Intermatic pool timer is a common issue. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. "url": "https://blog.intheswim.com/"
Does the tripper work on other areas of the clock, like near the off tripper? If I manually push the lever, it moves without much pressure. Any advice? The position of the metal bar forces the gear next to it to turn one way or another. I replaced the pump and still nothing is moving. Theres power to the pump using the manual override. Is it possible to do this by loosening the timer screw a bit? Move the switch and see that they separate when off, and come together when on. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. Ask Your Own Pool and Spa Question Does the manual lever stay in the on position always? I think I have found it. 2,767 Sq. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) A timer replacement would be required. Also be sure that the front dial is engaged with the gear located behind the dial. If its not, then the timer will not turn on/off at the correct times. My pump has a plug. Assuming the wiring is all correct. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Any other thoughts? Hi, new timer out of the box, 200V. I flicked the switch between on and off and it will not shut off. Any ideas? You can turn off Freeze protection and it should stop, or replace the probe if faulty. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Proceed to step 4 to check the timer itself. I bought new trippers. It is still moving and it will trip off but not on. Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow Basically youre eliminating possibilities until you find the cause. did i do something incorrectly? be sure the pins are pushed onto the edge of the dial fully. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. Ordered new ones. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Now it worksbut its really fast. The mechanism for the off tripper doesn't work at all when manually depressed. "logo": {
Hi Rhomell, are you sure you got the correct trippers? Hi Jere, that could be the timer motor failing. Check the wire connections to be sure they are tight, and look for any burnt wires. Replace a new T104. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Intermatic timers are a great addition to your pool set up but they can go wrong. However, after several hours, maybe overnight, the associated breaker will trip. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. Thanks. Related Reading: Should You Get a Pool Pump Timer? As an Amazon Associate we earn from qualifying purchases. My intermatic timer is not turning my pool pump on. You can replace the entire mechanism or the gears. Should it still not work, I suspect a motor failure for the clock. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Hi Davy, Ive reset the time 5 times and just realized that its going counter clockwise. It was always fine before. the timer was directly plugged into a gfci and the pump directly into the timer. That way I could schedule the pump once again. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. As you release the dial, you will feel the gears engage. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. Types of Pool Timers & How They Work - Pool Research "
Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. There's an issue with the wiring between the circuit breaker and the timer. What is the problem? I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. Advice? No broken or loose wires visible. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. If not, that sounds like a weak/bad motor. Rich. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. Partially loosen the screw that holds the "off" pin in place. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead.